Artificial intelligence and diagnostic reasoning in syncope
We thank Venunan, Rattanawong, and Shen for their careful, balanced, and clinically relevant commentary on our research into the diagnostic performance of artificial intelligence (AI) in patients with syncope (1,2). We particularly appreciate that they look beyond diagnostic yield alone and distinguish between generating possible diagnoses and prioritizing the most likely diagnosis. Their observation that syncope is not a “recall task” but, in essence, a “prioritization task” captures, in our view, the central challenge of both syncope care and the current limitations of large language models (LLMs).
Importantly, generative pre-trained transformer (GPT)-4o was not evaluated using a generic prompt. We developed a system prompt based on the 2018 European Society of Cardiology (ESC) guidelines for syncope and the accompanying Web Practical Instructions (2-4). Relevant guideline text, tables, and legends were included, whereas non-essential content and visual elements were removed. The final prompt comprised more than 90,000 tokens and was iteratively tested beforehand using clinical cases. GPT-4o had access to an extensive syncope-specific knowledge and instruction framework. Nevertheless, diagnostic precision, as defined in our paper, remained limited, and three out of the four patients ultimately diagnosed with cardiac syncope were initially classified as having reflex syncope (2).
In a subsequent analysis, we evaluated GPT-5 using structured data from the medical report from a syncope expert in a syncope unit (5). Again, the same GPT-4o prompt was used, and no additional training or fine-tuning was performed. GPT-5 was first provided with the guideline-based core evaluation (CE): a comprehensive medical history, physical examination, active standing test, and 12-lead electrocardiogram (ECG). The same patient was then reassessed after extended evaluation (EE), including additional diagnostic testing where indicated. One might expect an LLM, which is specifically designed to process large volumes of text and information, to benefit substantially from richer and more complete clinical data as provided by the medical report of the guideline-based syncope evaluation performed by the syncope expert in the syncope unit. This occurred only to a limited extent. GPT-5 included the adjudicated final diagnosis in 52% of cases after CE and 57% after EE (syncope expert), while the Diagnostic Precision Score remained negative in both after CE and EE (5). The limitation therefore appears not to reflect a lack of information alone, but rather the ability to weigh and prioritize clinical information and to calibrate diagnostic uncertainty appropriately.
By contrast, the syncope expert’s initial diagnosis did not change in any of the 55 patients after additional testing (5). Previous research showed that 93% of final diagnoses were established after the guideline-based initial evaluation (6-8). These findings support the principle that the guideline-based initial syncope evaluation, including a careful medical history, physical examination, active standing test, and ECG, remains the cornerstone of syncope evaluation. Additional investigations should therefore be performed when clinically indicated rather than routinely just to “complete” a diagnostic work-up. Notably, providing GPT-5 with additional information resulted in only a modest improvement and did not improve recognition of cardiac syncope.
A second important finding concerns consistency. Many studies evaluating the diagnostic performance of LLMs report results based on a single model output. We presented exactly the same case, using the same prompt and model settings, to GPT-5 on five independent occasions (5). The same top-ranked diagnosis was produced in all five runs in only 69% of patients after CE and 74% after EE. In the remaining patients, GPT-5 generated two or even three different top-ranked diagnoses, sometimes varying between a relatively benign reflex or orthostatic cause and cardiac syncope. This variability occurred despite a low temperature setting, which is intended to reduce stochasticity. A single LLM output should therefore not automatically be regarded as a stable “decision” by the model. In our view, repeated-run consistency should become a standard outcome measure in future research on diagnostic AI.
These limitations do not mean that LLMs have no value in syncope care. On the contrary, GPT-4o frequently provided structured recommendations that were less often mentioned by medical professionals, including additional testing, and lifestyle measures including increased fluid intake, physical counter-pressure manoeuvres and patient education (2). AI could also support systematic medication review, which may be particularly relevant because none of the referral letters in our original study documented medication review or adjustment before referral (2).
AI may therefore serve as a structured clinical checklist, prompting clinicians to consider whether further investigations are genuinely indicated, whether relevant medication has been reviewed, and whether practical guideline-based measures have been discussed. These may include adequate fluid intake, increased salt intake where appropriate, physical counter-pressure manoeuvres, and sitting or lying down promptly when recognizable prodromal symptoms occur. Moreover, AI may adequately emphasize the aspect of reassurance. In this role, AI would not replace clinical decision-making, but could improve the completeness and consistency of patient evaluation and management.
For future development, a robust reference standard remains essential to test the diagnostic yield and accuracy of AI. The ideal scenario would be to capture a spontaneous event with simultaneous continuous blood pressure and cardiac rhythm monitoring, but this is not feasible in most patients seen in the outpatient clinic. An independently adjudicated diagnosis by an expert committee after systematic longitudinal follow-up currently represents the best available reference standard for comparative diagnostic research in syncope (5,7-9). Future AI systems might improve through domain-specific training or fine-tuning using large numbers of well-characterized syncope cases with comprehensive follow-up and an independently adjudicated diagnosis. Crucially, this requires not simply more data, but high-quality data that can teach the model to distinguish between plausibility, probability, and clinical risk.
We are very grateful to Venunan et al. for their nuanced and clinically perceptive commentary. Our additional findings with GPT-5 reinforce their central message: current LLMs are strong in speed, breadth and structure, but remain limited in diagnostic prioritization, calibration of uncertainty and reproducibility. The most realistic role for AI in syncope care is therefore as a supportive tool within clinician-led pathways, while future progress will depend primarily on better training, robust reference standards and explicit attention to safety and reproducibility.
Acknowledgments
None.
Footnote
Provenance and Peer Review: This article was commissioned by the editorial office, Annals of Translational Medicine. The article did not undergo external peer review.
Funding: None.
Conflicts of Interest: Both authors have completed the ICMJE uniform disclosure form (available at https://atm.amegroups.com/article/view/10.21037/atm-2026-0208/coif). S.v.Z. received a travel grant to attend a scientific meeting from 10 to 12 May 2026. The other author has no conflicts of interest to declare.
Ethical Statement: The authors are accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.
References
- Venunan K, Rattanawong P, Shen WK. Artificial intelligence-based clinical diagnosis of syncope. Ann Transl Med 2026. [Epub ahead of print]. doi: 10.21037/atm-2026-0119.
- van Zanten S, Boel TT, de Jong JS, et al. Clinical Decision-Making of Artificial Intelligence vs Medical Professionals in Patients With Syncope. JACC Adv 2026;5:102426. [Crossref] [PubMed]
- Brignole M, Moya A, de Lange FJ, et al. 2018 ESC Guidelines for the diagnosis and management of syncope. Eur Heart J 2018;39:1883-948. [Crossref] [PubMed]
- Brignole M, Moya A, de Lange FJ, et al. Practical Instructions for the 2018 ESC Guidelines for the diagnosis and management of syncope. Eur Heart J 2018;39:e43-80. [Crossref] [PubMed]
- van Zanten S, Boel TT, de Jong JSY, et al. Diagnostic performance of artificial intelligence in the syncope unit. Explor Cardiol 2026;4:1012114.
- de Jong JSY, van Zanten S, Thijs RD, et al. Syncope Diagnosis at Referral to a Tertiary Syncope Unit: An in-Depth Analysis of the FAST II. J Clin Med 2023;12:2562. [Crossref] [PubMed]
- van Wijnen VK, Gans ROB, Wieling W, et al. Diagnostic accuracy of evaluation of suspected syncope in the emergency department: usual practice vs.ESC guidelines. BMC Emerg Med 2020;20:59.
- van Dijk N, Boer KR, Colman N, et al. High diagnostic yield and accuracy of history, physical examination, and ECG in patients with transient loss of consciousness in FAST: the Fainting Assessment study. J Cardiovasc Electrophysiol 2008;19:48-55. [Crossref] [PubMed]
- de Jong JSY, Blok MRS, Thijs RD, et al. Diagnostic yield and accuracy in a tertiary referral syncope unit validating the ESC guideline on syncope: a prospective cohort study. Europace 2021;23:797-805. [Crossref] [PubMed]