The potential utility of patient-reported range of motion after total knee arthroplasty
Editorial

The potential utility of patient-reported range of motion after total knee arthroplasty

Jack Weick, Harpreet S. Bawa

Department of Orthopaedic Surgery and Rehabilitation Medicine, University of Chicago Medicine and Biological Sciences, Chicago, Illinois 60637, USA

Correspondence to: Harpreet S. Bawa, MD. Department of Orthopaedic Surgery and Rehabilitation Medicine, University of Chicago Medicine and Biological Sciences, 5841 South Maryland Avenue MC 3079, Chicago, Illinois 60637, USA. Email: hbawa@uchicago.edu.

Submitted Jul 07, 2015. Accepted for publication Jul 16, 2015.

doi: 10.3978/j.issn.2305-5839.2015.07.15


Total knee arthroplasty (TKA) is a safe, cost-effective treatment for pain relief and improvement of knee function in patients with knee arthritis (1-3). The procedure has become extremely common in the United States: in 2008 alone, over 615,000 TKAs were performed (4) mainly driven by the high prevalence of symptomatic osteoarthritis (OA) (5). Candidates for the procedure typically have diminished quality of life due to persistent knee pain and significant functional limitation (1). OA is the main clinical indication for TKA (approximately 97% of cases) (6). Advanced OA is associated with reduced knee range of motion (ROM), which leads to increased disability (7,8): an individual requires 67° of knee flexion to walk normally, 83° of flexion to climb stairs, 90° to walk down stairs, 105° to get up from a chair, and 115° to rise from a sofa (9,10).

A variety of measures exist to assess the outcome after TKA, however, there is no universal standard (11). The American Knee Society Score (AKSS) is one of the most widely used scoring systems to assess knee functionality. It consists of both a clinical score and a functional score and is typically administered in office visits (12,13). ROM measurements are an integral component of the AKSS score. Final ROM achieved after TKA is an important determinant of both patient satisfaction and function (14,15). ROM is traditionally measured by clinicians or trained researchers using a goniometer to assess angle of flexion and extension. Goniometer measurements have been found to be highly reproducible between trained measurers when the same technique is used (16).

ROM after TKA is influenced by numerous factors including pre-operative ROM, age, body mass index, comorbidities (particularly diabetes mellitus), and intraoperative variables such as implant type and anesthesia modalities (17-22). Patients with stiffness and poor ROM post-TKA are typically managed first with aggressive physical therapy. If stiffness persists, patients may require more invasive measures such as manipulation under anesthesia (MUA) or arthroscopic lysis of adhesions. MUA is typically performed under general or regional anesthesia to allow complete muscle relaxation. The hip is flexed to 90° and the knee is bent until a firm end point is encountered. Although most patients experience improvements in ROM after MUA, patients with diabetes mellitus or patients who received a cruciate-retaining prosthesis have been found to be at risk for lower final ROM (23).

Long-term follow-up of patients after TKA is necessary. However, with the rapidly increasing population of patients undergoing TKA and its more prevalent use in younger patients, in-office follow-up can become burdensome and expensive (4,24). The necessity of using trained clinicians or technicians to measure ROM with a goniometer only amplifies the time and cost of in-office long-term follow-up visits. Questionnaires such as the Oxford Knee Score (25) attempt to assess patients’ evaluation of knee function and impact on quality of life. These questionnaires can be administered by phone, mail, or online thereby potentially reducing the need for an office visit, thus potentially reducing the burden on the healthcare system of long-term follow-up post-TKA. Although previous studies have shown a correlation between patient-reported questionnaires such as the Oxford Knee Score and more thorough knee evaluations such as the AKSS 2 years after TKA, no long-term (5 and 10 years post-TKA) correlation is observed (26). Furthermore, patient-reported questionnaires such as the Oxford Knee Score do not properly assess ROM, a vital component to evaluating knee functionality. Though the idea of self-reported outcomes such as the Oxford Knee Score present a potential way of reducing the burden of long-term post-operative follow-up, these simple at home questionnaires miss vital components of a more thorough clinical assessment.

A recent study by Collins et al. in the Journal of Arthroplasty proposed a new solution (27). This study utilized a method of patient-reported outcomes initially developed by Gioe et al. in which post-operative TKA patients were mailed surveys with lateral knee photographs that showed knee ROM in small increments to compare to their knee ROM (28). This method was further validated by Khanna et al. in 2011 (29). Khanna and colleagues compared patient-reported ROM using similar methods developed by Gioe et al. with clinically measured ROM using a goniometer. They stated that patient-reported ROM using photographs could be considered accurate for the purposes of long-term follow-up of patients after TKA. Patient recorded flexion assessed by the use of photographs was not significantly different than clinician-measured flexion as determined by goniometer measurements—a difference of just 0.7° (P=0.48). Although the assessment of extension was significantly different between the self-reported method and the clinician measurements (difference of 1.7°, P<0.001), the small absolute measurements of extension (often 1-4°) makes the comparison more difficult. Additionally, previous studies have shown a correlation between patient-report extension using photographs and physician-measure extension using a goniometer (28). These studies using patient-reported ROM with photographs only looked at patients after TKA. Understanding the ROM before TKA is important, as pre-operative ROM is the key determinant of post-operative ROM (17). Neither study evaluated change in patient-reported ROM over time or compared patient-reported ROM at baseline before surgery and after TKA.

To address these gaps in the data and further validate this patient-reported ROM methodology, Collins et al. enrolled 112 TKA patients. Subjects were assessed at baseline (pre-TKA), 3 months post-operatively, and 6 months post-operatively. ROM (both flexion and extension) were assessed either in office by goniometer measurement from a trained research assistant or at home using photographs depicting varying ranges of flexion and extension and asking the patients to select the photograph closest to their current ability to flex or extend. The authors found a statistically significant association between the objective measurements using the goniometer and self-reported ROM using the photograph method for both flexion and extension, thus further validating this method as a way of assessing ROM.

Collins and colleagues were also able to show that self-reporting of ROM using this method was valid over time: reports of improvement, worsening, or stable ROM was associated with clinical goniometer measured changes over time. This has important implications in long-term follow-up of TKA patients post-operatively. Younger patients generally have greater rates of revision of TKA than older patients likely due to longer required lifespan of the prosthesis as well as better post-operative health and mobility resulting in increased wear-and-tear (30). Additionally, as the lifespan of the population as a whole increases and the popularity of TKAs continue to rise, the number of knee arthroplasties that become functionally compromised years after the operation will continue to increase as well. Although the follow-up time used by Collins et al. was limited to 3 and 6 months, the accuracy of the changes in measurement over time suggest that this method may be valid for not only short term, but longer follow-up intervals as well.

As Collins demonstrated, the patient-reported ROM using photographs was sensitive to change—both increasing ROM and decreasing ROM. The ability to accurately detect changes in ROM over time is vital. Early detection of a change in ROM and instability can indicate early failure and therefore allow earlier intervention. Polyethylene wear can lead to osteolysis, deterioration of bone, and eventual loosening. This process can begin before a patient is symptomatic and may only be evident on radiographs (31). Often, patients do not present with a prosthesis in which function has become compromised until there is pain, sensation of instability, recurrent joint effusions, or dramatic decrease in functionality. Delayed detection can lead to a more technically challenging revision procedure because of decreased bone stock. However, with accurate patient-reported ROM in small, 5° increments as used by Collins and Khanna, it is possible that a potential impending failure can be detected earlier, before significant polyethylene wear and osteolysis occurs. Consequently, a partial or complete revision would likely have greater rates of success with early detection. In the immediate post-operative period evaluation of ROM patient progress can be recorded and intervention can be performed sooner if patients are not achieving an adequate arc of motion. Aggressive physical therapy is typically the first line intervention however if patients do not make adequate improvements with therapy alone then and MUA is indicated. Shorter intervals between TKA and any intervention allow greater success than if therapy or MUA are delayed and significant functional limitations have already been realized (23).

This study validated this patient-reported method and was able to show accurate measurements over time and changing ROM. The short-term follow-up time points used by Collins et al. (3 and 6 months post-operatively) are important as they can play a role in determining whether there is stiffness and poor ROM that needs treatment with physical therapy or MUA. Evidence suggests MUA within 90-day results in greater ROM compared to longer intervals (32,33). Although survival of TKAs is high years after the operation (10-year survival, 85-97%) (34,35), long-term follow-up on patients with TKA is needed as there are still a considerable number of patients requiring therapy or revision years after the operation. The results from Collins and colleagues suggest that this method may be valid with longer follow-up; however, future work confirming the ability of this method to detect changes in ROM and stability over a long time period post-operatively (5, 10, 15 years) would be ideal. Now that this methodology has been validated in several studies, there is a need for determination of the appropriate way to incorporate this patient-reported ROM into clinical practice. Clearly, this could reduce the number of in-office follow-up visits after TKA. However, the proper balance of patient-reported outcomes and evaluation by a clinician must be maintained to ensure proper long-term care for patients with a knee replacement. Additionally, cost-effective analysis of widespread, long-term employment of this technique is necessary to determine if this does truly benefit the healthcare system.

With the increasing prevalence of TKAs, validated patient-reported outcomes such as self-reported ROM using photographs as described above could help relieve some of the burden that is placed on both patients and the healthcare system with the necessary follow-up of patients with TKA. The cost and resource savings that could result from implementation of this technique could help make TKAs—which are already considered highly cost-effective (2)—even more efficient long-term result in significant savings in cost and resources.


Acknowledgements

None.


Footnote

Conflicts of Interest: The authors have no conflicts of interest to declare.


References

  1. NIH Consensus Panel. NIH Consensus Statement on total knee replacement December 8-10, 2003. J Bone Joint Surg Am 2004;86-A:1328-35. [PubMed]
  2. Daigle ME, Weinstein AM, Katz JN, et al. The cost-effectiveness of total joint arthroplasty: a systematic review of published literature. Best Pract Res Clin Rheumatol 2012;26:649-58. [PubMed]
  3. Beswick AD, Wylde V, Gooberman-Hill R, et al. What proportion of patients report long-term pain after total hip or knee replacement for osteoarthritis? A systematic review of prospective studies in unselected patients. BMJ Open 2012;2:e000435. [PubMed]
  4. Losina E, Thornhill TS, Rome BN, et al. The dramatic increase in total knee replacement utilization rates in the United States cannot be fully explained by growth in population size and the obesity epidemic. J Bone Joint Surg Am 2012;94:201-7. [PubMed]
  5. Nguyen US, Zhang Y, Zhu Y, et al. Increasing prevalence of knee pain and symptomatic knee osteoarthritis: survey and cohort data. Ann Intern Med 2011;155:725-32. [PubMed]
  6. Paxton EW, Namba RS, Maletis GB, et al. A prospective study of 80,000 total joint and 5000 anterior cruciate ligament reconstruction procedures in a community-based registry in the United States. J Bone Joint Surg Am 2010;92:117-32. [PubMed]
  7. Steultjens MP, Dekker J, van Baar ME, et al. Range of joint motion and disability in patients with osteoarthritis of the knee or hip. Rheumatology (Oxford) 2000;39:955-61. [PubMed]
  8. Pisters MF, Veenhof C, van Dijk GM, et al. The course of limitations in activities over 5 years in patients with knee and hip osteoarthritis with moderate functional limitations: risk factors for future functional decline. Osteoarthritis Cartilage 2012;20:503-10. [PubMed]
  9. Kettelkamp DB. Gait characteristics of the knee: normal, abnormal, and post-reconstructive. In: American Academy of Orthopaedic Surgeons Symposium on Reconstructive Surgery of the Knee. St. Louis, MO: CV Mosby, 1976:47-57.
  10. Laubenthal KN, Smidt GL, Kettelkamp DB. A quantitative analysis of knee motion during activities of daily living. Phys Ther 1972;52:34-43. [PubMed]
  11. Bourne RB. Measuring tools for functional outcomes in total knee arthroplasty. Clin Orthop Relat Res 2008;466:2634-8. [PubMed]
  12. Liow RY, Walker K, Wajid MA, et al. The reliability of the American Knee Society Score. Acta Orthop Scand 2000;71:603-8. [PubMed]
  13. Singh J, Sloan JA, Johanson NA. Challenges with health-related quality of life assessment in arthroplasty patients: problems and solutions. J Am Acad Orthop Surg 2010;18:72-82. [PubMed]
  14. Schurman DJ, Parker JN, Ornstein D. Total condylar knee replacement. A study of factors influencing range of motion as late as two years after arthroplasty. J Bone Joint Surg Am 1985;67:1006-14. [PubMed]
  15. Jacobs CA, Christensen CP. Factors influencing patient satisfaction two to five years after primary total knee arthroplasty. J Arthroplasty 2014;29:1189-91. [PubMed]
  16. Edwards JZ, Greene KA, Davis RS, et al. Measuring flexion in knee arthroplasty patients. J Arthroplasty 2004;19:369-72. [PubMed]
  17. Ritter MA, Campbell ED. Effect of range of motion on the success of a total knee arthroplasty. J Arthroplasty 1987;2:95-7. [PubMed]
  18. Ritter MA, Stringer EA. Predictive range of motion after total knee replacement. Clin Orthop Relat Res 1979.115-9. [PubMed]
  19. Bong MR, Di Cesare PE. Stiffness after total knee arthroplasty. J Am Acad Orthop Surg 2004;12:164-71. [PubMed]
  20. Kim J, Nelson CL, Lotke PA. Stiffness after total knee arthroplasty. Prevalence of the complication and outcomes of revision. J Bone Joint Surg Am 2004;86-A:1479-84. [PubMed]
  21. Bolognesi MP, Marchant MH Jr, Viens NA, et al. The impact of diabetes on perioperative patient outcomes after total hip and total knee arthroplasty in the United States. J Arthroplasty 2008;23:92-8. [PubMed]
  22. Scuderi GR. The stiff total knee arthroplasty: causality and solution. J Arthroplasty 2005;20:23-6. [PubMed]
  23. Bawa HS, Wera GD, Kraay MJ, et al. Predictors of range of motion in patients undergoing manipulation after TKA. Clin Orthop Relat Res 2013;471:258-63. [PubMed]
  24. Culliford DJ, Maskell J, Beard DJ, et al. Temporal trends in hip and knee replacement in the United Kingdom: 1991 to 2006. J Bone Joint Surg Br 2010;92:130-5. [PubMed]
  25. Dawson J, Fitzpatrick R, Murray D, et al. Questionnaire on the perceptions of patients about total knee replacement. J Bone Joint Surg Br 1998;80:63-9. [PubMed]
  26. Medalla GA, Moonot P, Peel T, et al. Cost-benefit comparison of the Oxford Knee score and the American Knee Society score in measuring outcome of total knee arthroplasty. J Arthroplasty 2009;24:652-6. [PubMed]
  27. Collins JE, Rome BN, Daigle ME, et al. A comparison of patient-reported and measured range of motion in a cohort of total knee arthroplasty patients. J Arthroplasty 2014;29:1378-1382.e1
  28. Gioe TJ, Pomeroy D, Suthers K, et al. Can patients help with long-term total knee arthroplasty surveillance? Comparison of the American Knee Society Score self-report and surgeon assessment. Rheumatology (Oxford) 2009;48:160-4. [PubMed]
  29. Khanna G, Singh JA, Pomeroy DL, et al. Comparison of patient-reported and clinician-assessed outcomes following total knee arthroplasty. J Bone Joint Surg Am 2011;93:e117(1)-(7).
  30. Kennedy LG, Newman JH, Ackroyd CE, et al. When should we do knee replacements? Knee 2003;10:161-6. [PubMed]
  31. Engh CA Jr, Ho H, Padgett DE. The surgical options and clinical evidence for treatment of wear or corrosion occurring with THA or TKA. Clin Orthop Relat Res 2014;472:3674-86. [PubMed]
  32. Daluga D, Lombardi AV Jr, Mallory TH, et al. Knee manipulation following total knee arthroplasty. Analysis of prognostic variables. J Arthroplasty 1991;6:119-28. [PubMed]
  33. Namba RS, Inacio M. Early and late manipulation improve flexion after total knee arthroplasty. J Arthroplasty 2007;22:58-61. [PubMed]
  34. Vessely MB, Whaley AL, Harmsen WS, et al. The Chitranjan Ranawat Award: Long-term survivorship and failure modes of 1000 cemented condylar total knee arthroplasties. Clin Orthop Relat Res 2006.28-34. [PubMed]
  35. Rasquinha VJ, Ranawat CS, Cervieri CL, et al. The press-fit condylar modular total knee system with a posterior cruciate-substituting design. A concise follow-up of a previous report. J Bone Joint Surg Am 2006;88:1006-10. [PubMed]
Cite this article as: Weick J, Bawa HS. The potential utility of patient-reported range of motion after total knee arthroplasty. Ann Transl Med 2015;3(14):193. doi: 10.3978/j.issn.2305-5839.2015.07.15

Download Citation