A randomized controlled trial: evaluation of efficiency and safety of a novel surgical guide in the extraction of deeply impacted supernumerary teeth in the anterior maxilla
Introduction
Supernumerary teeth are common clinical dental anomalies, which may lead to diastema, disturbances in tooth eruption, root resorption, dentigerous cysts, and other problems (1,2). At present, the treatment modalities are still inconsistent due to the difficulty and risk of locating the impacted supernumerary teeth during the operation (3). Nevertheless, the majority of studies suggest surgical extraction to be the primary treatment (4-6).
Preoperative X-ray and cone-beam computed tomography (CBCT) are helpful for locating superficial supernumerary teeth (7), but for deeply impacted supernumerary teeth (DIMSNT), these methods are imprecise (8,9). In the freehand operation of DIMSNT, a point was selected as a reference by the surgeon. To expose the operative area adequately, a wide incision was made and the mucoperiosteal flap was turned up. The surgeon removes the bone in the reference point to expose and extract the DIMSNT. The freehand operation of DIMSNT may cause damage to adjacent structures such as the potential nasopalatine nerve and the roots of the adjacent permanent teeth injury, which would affect the operation time, the incidence of trauma or complications, and the surgeon’s confidence (10,11).
There has been increasing interest in osteotomy guide plates used to guide surgery in recent years (12). Recent evidence suggests that the osteotomy guide plate can reduce the risk and the difficulty during the operation of DIMSNT (13-18). Jo et al. reported that for 2 complicated DIMSNT, the osteotomy guide plate was used to avoid damage to adjacent teeth (19). The main disadvantage of the osteotomy guide is that it cannot guide the incision, and the angle and depth of bone removed during the operation may cause damage and may increase the risk of the procedure. Wang et al., through the operation navigation system, extracted DIMSNT successfully during the operation (20). However, navigation systems require a significant monetary investment. The cost of using this technology on an individual is not unacceptable. The much-debated question is how to design a surgical guide for incision consistent with osteotomy during the operation. There is little published data on this issue. In order to resolve the question, Liu et al. used the split guide plate for the osteotomy, but also the incision, successfully guiding labially approachable mesiodens (21). Nevertheless, the split guide plate is only suitable for impacted mesiodens on the labial side. A novel digital surgical guide has been designed with both incision and osteotomy navigation functions, which may achieve extract DIMSNT minimally invasive by navigating precisely. The surgical guide may be able to solve the problem of serious postoperative complications caused by the imprecise position surgery. This study attempted to design a novel digital surgical guide and explored its efficiency and safety in DIMSNT extraction.
The main objective of study was to optimize the surgical guide plate and compare the clinical effect and operative time between freehand and guided surgery in the extraction of DIMSNT. By performing comparative analysis of data, we evaluated the application value of the surgical guide in the area of DIMSNT surgery. We present the following article in accordance with the CONSORT reporting checklist (available at https://atm.amegroups.com/article/view/10.21037/atm-22-585/rc).
Methods
Study design
In our study, a new classification of DIMSNT was made based on the conceptual framework proposed by Liu et al. (9). In brief, type I: low position (the lowest point of supernumerary teeth is below the neck of adjacent permanent teeth); type II: middle position (the lowest point of supernumerary teeth is between the apex and neck of adjacent permanent teeth); type III: high position (the lowest point of supernumerary teeth is above the apex of adjacent permanent teeth) (Figure 1). Among these types, type II/III was defined as DIMSNT.
Patients with DIMSNT treated at the Department of School & Hospital of Stomatology, Wenzhou Medical University, were enrolled in the study from March 2019 to December 2020.
In this study, a randomized controlled trial was performed and 40 patients with DIMSNT in the anterior maxilla were randomly divided into two groups (allocation ratio is 1:1) were collected for the extraction. The randomization process was conducted by items 8–10 of the CONSORT statement 2001 checklist for randomized controlled clinical trials (22). Participants were allocated to one of the two groups by asking them to pick one of the sequentially numbered, opaque sealed envelopes containing any of the two interventions. Each participant had an equal chance of being assigned to one of the two groups. Participants are blinded to the allocation. During the single-blind study, randomization was conducted by the same hospital nurse who had research experience and was not involved in any trial section. All patients were treated with general anesthesia, and the same senior surgeon performed all the surgeries. Patients with any of the following were excluded from the study: acute infections; systemic diseases such as diabetes and blood dyscrasias; history of alcoholism, drug abuse, or heavy smoking; and severe psychiatric disease.
The study was conducted in accordance with the Declaration of Helsinki (as revised in 2013). The study was approved by ethics board of School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China (No. WYKQ2019008) and informed consent was taken from all the patients.
Design process of the surgical guide
The preoperative CBCT data of patients (120 kV, 6 mA, 6 cm × 6 cm FOV, 0.3 mm voxel, 8.9-s scan time) were stored on a disk as Digital Imaging and Communications in Medicine (DICOM) files, using Mimics, version 18.0 (Materialise, Leuven, Belgium) software to perform the 3D reconstruction. An optical scanner was used to obtain the maxillary cast model information for each patient, which was then imported into the software. The model information reconstructed by CT in the 3D space was overlapped and matched to accurately restore the patient’s crown and mucosal structures. The operation approach was determined by computer measurement and analysis (Figure 2).
The surgical guide plate was designed in 3 parts: the incision guide plate, osteotomy guide plate, and installation groove. The installation groove connects with the incision guide plate as a whole. The incision guide plate as an arch shape connects with the osteotomy guide plate by a T-slot. The fixing part of the installation groove matches with the teeth for stability (Figure 3).
The position of the incision guide plate was determined by the projection image of DIMSNT. The shape of the incision was designed as an arch to ensure blood supply and to apply the osteotomy guide plate to placement (Figure 4A,4B).
The position and shape of the osteotomy guide plate were determined by the projection image of the bone surface of DIMSNT. The depth of DIMSNT determined the osteotomy guide’s height, guiding the depth of bone removal. The edge curvature of the osteotomy guide plate was designed with the contour of DIMSNT to guide the angle of bone removal (Figure 4C-4F). Then, the surgical guide was fabricated through manual procedures based on the measurements (Figure 5).
Surgical techniques
In group I, the surgeon embedded the fixing part of the installation groove in the occlusal surfaces of teeth for stability, and the incision was made according to the guide (Figure 6A). The mucoperiosteal flap was turned up and the osteotomy guide was fixed with the T-slot (Figure 6B). The route and depth of bone removal were guided by the internal edge and the height of the osteotomy guide plate (Figure 6C,6D). During the procedure, the drill was moved against the osteotomy guide’s inner edge and attention was paid to the depth of bone removal. Then, the bone was removed to expose DIMSNT and perform extraction. Finally, the mucosal incision was sutured using a 4-0 braid suture after washing by 0.9% physiological saline (Figure 6E,6F). In group II, the surgeon used a gingival margin incision and made the trapezoidal flap. The other steps were the same as those except for the guide in group I. The sutures were removed 1 week after the operation.
Record indicators and evaluation criteria
In this study, intraoperative and postoperative assessments were used to measure the efficacy and safety of the novel surgical guide, and 2 surgeons performed evaluations independently to make a judgment.
The following data were evaluated intraoperatively to measure the efficacy of the novel surgical guide
- Operation time (primary endpoint): the time from incision to the end of the suture.
- The number of cases requiring additional osteotomy after lifting the bone followed by extraction of DIMSNT was recorded as an indicator of the accuracy of the osteotomy (primary endpoint).
The following data were evaluated postoperatively to measure the safety of the novel surgical guide
- Swelling and pain degree on the 1st, 3rd, and 7th days after the operation (primary endpoint): the visual analogue scale (VAS) was used to evaluate the pain degree (23), and the total VAS score was 10. The higher the value, the higher the degree of pain. The surgeons’ subjective evaluation index was used to evaluate the degree of swelling. Evaluation criteria for swelling: (i) no swelling; (ii) slight swelling; (iii) moderate swelling; (iv) severe swelling.
- Patients were discharged from the hospital with a satisfaction survey score of 10 (secondary endpoint). Scores of 9–10 were very satisfied, 6–8 were satisfied, and <6 were dissatisfied.
Statistical analysis
The Kruskal-Wallis rank-sum or nonparametric test was performed using SPSS 20.0 software (IBM SPSS, Inc., Chicago, IL, USA). Normally distributed data were presented in the form of mean ± standard deviation. Furthermore, the P value for the two-sided test and a P value of less than 0.05 was accepted as statistically significant.
Results
This study enrolled 52 patients and excluded 12 patients from March 2019 to December 2020. The remaining 40 patients were randomly divided between group I (20 cases) and group II (20 cases). One-week postoperative follow-up for every patient. None of the patients were lost to follow-up. Nine out of the 20 patients were females, 11 were males, and the mean of their ages was 9.4±3.85 years (range, 5–22 years) in group I. Eight out of the 20 patients were females, 12 were males, and the mean of their ages was 9.52±4.35 years (range, 6–25 years) in group II (Figure 7).
All guide templates were positioned smoothly and conformed to the bone surface during the operation. However, one of the surgical guide plates was fractured during the operation. All the supernumerary teeth were extracted uneventfully. There were no significant differences in age, sex, impacted depth, direction, and location among the two groups. Thus, the two groups were comparable (Table 1).
Table 1
Variable | Template group | Freehand group | F value | P value |
---|---|---|---|---|
Gender | 0.097 | 0.756 | ||
Male | 11 | 12 | ||
Female | 9 | 8 | ||
Age, years | 9.4±3.85 | 9.52±4.35 | 0.001 | 0.97 |
Depth | 0.095 | 0.759 | ||
II (middle) | 11 | 10 | ||
III (high) | 9 | 10 | ||
Location | 0.150 | 0.701 | ||
Palatal side | 18 | 18 | ||
Labial side | 1 | 2 | ||
Arch | 1 | 0 | ||
Direction | 1.114 | 0.297 | ||
Inversion | 12 | 14 | ||
Vertical | 2 | 3 | ||
Incline | 5 | 3 | ||
Horizontal | 1 | 0 |
F value, ratio of two mean squares.
The following outcomes of efficacy
The Kruskal-Wallis rank-sum test showed that the operation time of group I was significantly shorter than group II (P=0.0194; Table 2). Five cases needed additional osteotomy in group I, and 15 cases needed additional osteotomy in group II due to insufficient tooth exposure after lifting the bone. In one of the cases, the plate was fractured during the operation.
Table 2
Group | Operative time, min |
---|---|
Template group | 23.35±5.39 |
Freehand group | 29.60±9.76 |
P value | 0.0194 |
F value | 5.963 |
F value, ratio of two mean squares.
The following outcomes of safety
The pain degree of group I on the 1st (P=0.0401), 3rd (P=0.0247), and 7th (P=0.0382) postoperative days was significantly less than group II (Table 3). The swelling degree of group I on the 1st, 3rd, and 7th postoperative days was significantly less than group II (Table 4). Patient satisfaction was significantly higher in group I than in group II (P=0.0152; Table 5).
Table 3
Days | Template group | Freehand group | F value | P value |
---|---|---|---|---|
1 day | 2.10±0.99 | 2.95±1.43 | 4.519 | 0.0401 |
3 days | 2.60±1.20 | 3.80±1.88 | 5.472 | 0.0247 |
7 days | 0.70±1.05 | 1.70±1.73 | 4.612 | 0.0382 |
F value, ratio of two mean squares.
Table 4
Days | Template group | Freehand group |
---|---|---|
1 day | 38 | 39 |
3 days | 40 | 58 |
7 days | 24 | 37 |
Table 5
Group | Cases | Very satisfied | Basically satisfied | Dissatisfied | Score |
---|---|---|---|---|---|
Template group | 20 | 15 | 5 | 0 | 8.95±1.05 |
Freehand group | 20 | 9 | 9 | 2 | 7.90±1.51 |
P value | – | – | – | – | 0.0152 |
F value | – | – | – | – | 6.470 |
F value, ratio of two mean squares.
Discussion
We designed a novel surgical guide plate including an incision and osteotomy guide to navigate the surgery for DIMSNT. This study demonstrates that the novel surgical guide plate can expose the DIMSNT to perform immediate extraction after the plate is removed. Prior studies have noted the importance of locating the DIMSNT during the operation (24). Studies have shown the advantages of the osteotomy guide plate for the extraction of DIMSNT (13-18), but it only indicates the area of DIMSNT without navigation. Retana et al., to overcome these defects, designed a dynamic surgical navigation system to expose the DIMSNT (25). Although navigation systems can be used for precise bone removal, they do not have broad application prospects for clinical use. Based on existing research, we improved the osteotomy guide plate to shape the supernumerary tooth. The bone is removed according to the height and edge slope of the osteotomy plate during the operation. Through precise positioning, the DIMSNT can be exposed and extracted immediately. For the design of the surgical guide plate compared with the navigation system, we chose the method of point to point to guide the surgery, which may be more imprecise than the navigation system. Nevertheless, we simplified the structure of the guide and overcame several of the limitations of navigation-assisted extraction.
Additionally, we compared the effect of the novel surgical guide with the traditional group. This study found that the surgical guide plates can significantly reduce the operation time and postoperative complications. A possible explanation for this might be the precise exposure of the DIMSNT (2,26-28). At the same time, the results indicate that surgical guide plates can enhance patients’ satisfaction scores, which may be explained by a reduction in operative time and postoperative complications.
For the incision design of DIMSNT surgery, the traditional methods use gingival or posterior gingival incision to expose the surface of the bone. Inappropriate incision may lead to increased damage, inadequate bone exposure, and nerve injury. In order to solve the above problems, some studies on incision guide plates have focused on approaching from the labial side of the maxilla. Zheng et al. had the outer edge of the guide positioning component designed as a soft tissue incision line and the inner edge as an osteotomy area to guide labially approachable mesiodens in patients (28). However, the research ignored the approach from the plate side of the maxilla. Based on this, our study innovated the incision guide plate applicable to the labial and palate side. The incision guide plate was designed as an arch shape to guarantee the flap’s blood supply and ensure space for osteotomy guide plate placement. Simultaneously, it connected with the osteotomy guide plate in the form of a T-slot, which effectively realized the transfer of 2 surfaces stably and precisely.
The application of the surgical guide plate in oral surgery still has its limitations. Firstly, in this study, 3 patients had errors in image acquisition during presurgical procedures which led to inadequate exposure of DIMSNT during surgery (19). It is necessary to try the surgical guide plate on patients before surgery. due to differences that may be found between the preoperative analysis data and the actual surgery. Secondly, our study showed that the swelling score of group I was higher than group II in some cases. It seems possible that these results are due to the expanded incision size to accommodate the osteotomy guide plate. Limited space available for oral surgery and placing the guide plate in the deep anatomical area will affect the vision of surgeons and the operation space, and can increase the operation time (21). At the same time, 2 cases needed additional osteotomy in group I, it might the drill placement imprecisely due to the limited space available for oral surgery. Finally, in one of the cases, the plate was fractured during the operation. This finding was unexpected and suggested that the material of the surgical guide was not adequate to withstand the pressure during surgery.
This study only included general anesthesia cases because of the complexity of the oral environment and the differing degrees of patient cooperation. However, it may have a broad application prospect under local anesthesia. When patients are diagnosed, they can communicate, undergo CBCT scanning, provide the oral impression when necessary, wait for the guide to be manufactured, and then revisit the clinic for surgery. Through the use of the surgical guide, the operation time can be shortened, surgical trauma can be reduced, patient fears about the tooth extraction process can be reduced (29), and the doctor-patient relationship can be improved (30).
Conclusions
In conclusion, the novel surgical guide plate can enhance patient satisfaction, shorten the operation time, and improve the operation quality by facilitating precise osteotomies and incisions. Although the novel surgical guide still has some flaws, we believe it has a broad application prospect for clinical use.
Acknowledgments
Funding: This work was supported by the National Natural Science Foundation of China (No. 31870971).
Footnote
Reporting Checklist: The authors have completed the CONSORT reporting checklist. Available at https://atm.amegroups.com/article/view/10.21037/atm-22-585/rc
Trial Protocol: Available at https://atm.amegroups.com/article/view/10.21037/atm-22-585/tp
Data Sharing Statement: Available at https://atm.amegroups.com/article/view/10.21037/atm-22-585/dss
Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at https://atm.amegroups.com/article/view/10.21037/atm-22-585/coif). The authors have no conflicts of interest to declare.
Ethical Statement: The authors are accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved. The study was conducted in accordance with the Declaration of Helsinki (as revised in 2013). The study was approved by ethics board of School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China (No. WYKQ2019008) and informed consent was taken from all the patients.
Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.
References
- Altan H, Akkoc S, Altan A. Radiographic characteristics of mesiodens in a non-syndromic pediatric population in the Black Sea region. J Investig Clin Dent 2019;10:e12377. [Crossref] [PubMed]
- Hamza H. Computer-Assisted Technique for Surgical Tooth Extraction. Int J Dent 2016;2016:7484159. [Crossref] [PubMed]
- Shah A, Gill DS, Tredwin C, et al. Diagnosis and management of supernumerary teeth. Dent Update 2008;35:510-2, 514-6, 519-20. [Crossref] [PubMed]
- Kim KS, Mun SK. Extensive dentigerous cyst associated with a mesiodens: CT findings. Ear Nose Throat J 2013;92:E6-8. [Crossref] [PubMed]
- Murali RV, Gnanashanmugam K, Rajasekar L, et al. A rare case of impacted supernumerary premolar causing resorption of mandibular first molar. J Pharm Bioallied Sci 2015;7:S309-13. [Crossref] [PubMed]
- Tyrologou S, Koch G, Kurol J. Location, complications and treatment of mesiodentes--a retrospective study in children. Swed Dent J 2005;29:1-9. [PubMed]
- Kapila S, Conley RS, Harrell WE Jr. The current status of cone beam computed tomography imaging in orthodontics. Dentomaxillofac Radiol 2011;40:24-34. [Crossref] [PubMed]
- Guerrero ME, Shahbazian M, Elsiena Bekkering G, et al. The diagnostic efficacy of cone beam CT for impacted teeth and associated features: a systematic review. J Oral Rehabil 2011;38:208-16. [Crossref] [PubMed]
- Liu DG, Zhang WL, Zhang ZY, et al. Three-dimensional evaluations of supernumerary teeth using cone-beam computed tomography for 487 cases. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007;103:403-11. [Crossref] [PubMed]
- Sukegawa S, Kanno T, Kawakami K, et al. Use of a Piezosurgery Technique to Remove a Deeply Impacted Supernumerary Tooth in the Anterior Maxilla. Case Rep Dent 2015;2015:974169. [Crossref] [PubMed]
- Zhao J, Liu N, Shen ML, et al. Clinical analysis of impacted supernumerary teeth in 115 patients. Shanghai Kou Qiang Yi Xue 2019;28:426-9. [PubMed]
- Li H, Fan W, Zhu X. Three-dimensional printing: The potential technology widely used in medical fields. J Biomed Mater Res A 2020;108:2217-29. [Crossref] [PubMed]
- Azarmehr I, Stokbro K, Bell RB, et al. Surgical Navigation: A Systematic Review of Indications, Treatments, and Outcomes in Oral and Maxillofacial Surgery. J Oral Maxillofac Surg 2017;75:1987-2005. [Crossref] [PubMed]
- Chen X, Xu L, Sun Y, et al. A review of computer-aided oral and maxillofacial surgery: planning, simulation and navigation. Expert Rev Med Devices 2016;13:1043-51. [Crossref] [PubMed]
- Dawood A, Marti Marti B, Sauret-Jackson V, et al. 3D printing in dentistry. Br Dent J 2015;219:521-9. [Crossref] [PubMed]
- Demian N, Pearl C, Woernley TC 3rd, et al. Surgical Navigation for Oral and Maxillofacial Surgery. Oral Maxillofac Surg Clin North Am 2019;31:531-8. [Crossref] [PubMed]
- Louvrier A, Marty P, Barrabé A, et al. How useful is 3D printing in maxillofacial surgery? J Stomatol Oral Maxillofac Surg 2017;118:206-12. [Crossref] [PubMed]
- Prasad TS, Sujatha G, Muruganandhan J, et al. Three-dimensional Printing in Reconstructive Oral and Maxillofacial Surgery. J Contemp Dent Pract 2018;19:1-2. [Crossref] [PubMed]
- Jo C, Bae D, Choi B, et al. Removal of Supernumerary Teeth Utilizing a Computer-Aided Design/Computer-Aided Manufacturing Surgical Guide. J Oral Maxillofac Surg 2017;75:924.e1-9. [Crossref] [PubMed]
- Wang J, Cui NH, Guo YJ, et al. Navigation-Guided Extraction of Impacted Supernumerary Teeth: A Case Report. J Oral Maxillofac Surg 2017;75:1136.e1-5. [Crossref] [PubMed]
- Liu PC, Wang ZX. Application of surgical locating guides on impacted supernumerary teeth extraction. Hua Xi Kou Qiang Yi Xue Za Zhi 2019;37:58-61. [PubMed]
- Moher D, Schulz KF, Altman DG. The CONSORT statement: revised recommendations for improving the quality of reports of parallel-group randomised trials. Lancet 2001;357:1191-4. [Crossref] [PubMed]
- Thong ISK, Jensen MP, Miró J, et al. The validity of pain intensity measures: what do the NRS, VAS, VRS, and FPS-R measure? Scand J Pain 2018;18:99-107. [Crossref] [PubMed]
- Liu M, Yang X, Lv K, et al. Minimally-invasive alternative to the extraction of deeply-impacted supernumerary teeth using a computer-designed surgical template. Br J Oral Maxillofac Surg 2019;57:285-7. [Crossref] [PubMed]
- Retana A, Emery RW, Keir V. Removal of Impacted Supernumerary Teeth Using a Dynamic Surgical Navigation System: A Case Report. J Oral Maxillofac Surg 2019;77:1130-4. [Crossref] [PubMed]
- El Kholy K, Lazarin R, Janner SFM, et al. Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery. Clin Oral Implants Res 2019;30:1067-75. [Crossref] [PubMed]
- Wu ZY, Alzuhair A, Kim H, et al. Magnetic resonance imaging based 3-dimensional printed breast surgical guide for breast-conserving surgery in ductal carcinoma in situ: a clinical trial. Sci Rep 2020;10:18534. [Crossref] [PubMed]
- Zheng X, Zhao J, Liu S, et al. Application of a surgical guide in the extraction of impacted mesiodentes: a randomized controlled trial. Clin Oral Investig 2021;25:2999-3006. [Crossref] [PubMed]
- López-Jornet P, Camacho-Alonso F, Sanchez-Siles M. Assessment of general pre and postoperative anxiety in patients undergoing tooth extraction: a prospective study. Br J Oral Maxillofac Surg 2014;52:18-23. [Crossref] [PubMed]
- Caltabiano ML, Croker F, Page L, et al. Dental anxiety in patients attending a student dental clinic. BMC Oral Health 2018;18:48. [Crossref] [PubMed]
(English Language Editor: C. Betlazar-Maseh)